Leave Your Message

Ultra-Micro Spectrophotometer

Aurora-900 is a full-wavelength(190-850nm) ultra-micro ultraviolet-visible spectrophotometer that does not require a computer. It can quickly and accurately detect nucleic acids, proteins, and cell solutions. Additionally, it is equipped with a cuvette mode for measuring the concentration of bacterial cultures and other solutions.

For nucleic acid detection, the Aurora-900 requires only 0.5 to 2µL of sample per measurement. Simply place the sample directly onto the sample plate—no need for cuvettes or capillaries. After measurement, the sample can either be wiped off or recovered using a pipette. The entire process is simple, fast, and seamless.

This instrument is widely applicable in various fields, including:

    Product Description

    Aurora-900 is a full-wavelength(190-850nm) ultra-micro ultraviolet-visible spectrophotometer that does not require a computer. It can quickly and accurately detect nucleic acids, proteins, and cell solutions. Additionally, it is equipped with a cuvette mode for measuring the concentration of bacterial cultures and other solutions.
    For nucleic acid detection, the Aurora-900 requires only 0.5 to 2µL of sample per measurement. Simply place the sample directly onto the sample plate—no need for cuvettes or capillaries. After measurement, the sample can either be wiped off or recovered using a pipette. The entire process is simple, fast, and seamless.
    This instrument is widely applicable in various fields, including:

    Clinical disease diagnosis
    Blood transfusion safety
    Forensic identification
    Environmental microbial testing
    Food safety testing
    Molecular biology research

    Basic Operation Instructions

    Schematic Diagram of Structure
    312099B2-8C04-4e42-8A68-01A39A6725FE图片2
    Normal working conditions:

    Environment Temperature: 5℃~40℃
    Humidity: ≤80%
    Power Supply: DC24V 

    Basic parameters and performance:

    Model

    Aurora-900

    Operation interface

    7 inch touch screen

    1024×600HD display

    Wavelength range

    190-850nm

    Sample volume

    0.5-2μL

    Light Range

    0.2mm,0.05mm(High concentration measurement)1.0mm(General concentration measurement)

    Nucleic acid testing range

    2-15000ng/μl (dsDNA)

    Light source

    Xenon flashing light

    Detectors

    HAMAMATSU UV-enhanced CMOS Line Array Sensors

    Absorbance Accuracy

    0.003Abs(0.2mm Light Range)

    Absorbance Accuracy

    ±1%(7.332Abs at 260nm)

    Absorbance range

    (Equivalent to 10mm)

    0.04 - 300A

    Testing time

    <6S

    OD600

    Absorbance range:0~6.000 Abs

    Power adapter

    DC 24V

     

    Absorbance stability:

    [0,3)≤0.5%, [3,4)≤2%

    Power consumption

    25W

     

    Repeatability of absorbance:0,3)≤0.5%, [3,4)≤2%

    Power consumption at standby

    5W

    Operating System

    Android OS

    Size

    200mm*260mm*165mm

    Weight

    5KG

     

     

    Operation Guide

    图片3
    Click on “Nucleic acid test”: enter the nucleic acid test interface.
    Click “Protein test”: enter the protein test interface.
    Click”Colorimetric method”: enter the colorimetric interface.
    Click”UvVis”: enter the UV detection interface.
    Click”OD600”: enter the OD600 detection interface.
    Click”system setting”: enter the system setting interface.
    Advantagessign up
    Product material:Magnet inside (NdFeB),PTFE coated
    1.Non-toxic
    2.Non-stick
    3.Acid and alkali resistant
    4.corrosion resistant
    5.eco-friendly
    6.preferential price
    7.Good magnetic properties
    8.High quality
    9.High temperature and low temperature
    10.various specifications and types